GA 90-160s – 50 Hz
Technical specifications (metric units)
| Type | Maximum working pressure | Capacity FAD (1) | Installed motor power | Noise level (2) | Weight | |||
| Type | Standard | Full Feature (3) | Standard / Full Feature (3) | kW | dB(A) | Standard | Full Feature (3) | |
| Type | bar(e) | l/s | m³/min | kW | dB(A) | kg | ||
| GA 90s | 5.5 | 5.3 | 353 | 21.2 | 90 | 76 | 2800 | 3200 |
| GA 90s | 7.5 | 7.3 | 297 | 17.8 | 90 | 76 | 2800 | 3200 |
| GA 90s | 8.5 | 8.3 | 284 | 17.0 | 90 | 76 | 2800 | 3200 |
| GA 90s | 10 | 9.8 | 260 | 15.6 | 90 | 76 | 2800 | 3200 |
| GA 110s | 5.5 | 5.3 | 424 | 25.4 | 110 | 77 | 2700 | 3100 |
| GA 110s | 7.5 | 7.3 | 370 | 22.2 | 110 | 77 | 2700 | 3100 |
| GA 110s | 8.5 | 8.3 | 347 | 20.8 | 110 | 77 | 2700 | 3100 |
| GA 110s | 10 | 9.8 | 316 | 19.0 | 110 | 77 | 2700 | 3100 |
| GA 132s | 5.5 | 5.3 | 502 | 30.1 | 132 | 78 | 2800 | 3200 |
| GA 132s | 7.5 | 7.3 | 440 | 26.4 | 132 | 78 | 2800 | 3200 |
| GA 132s | 8.5 | 8.3 | 414 | 24.8 | 132 | 78 | 2800 | 3200 |
| GA 132s | 10 | 9.8 | 382 | 22.9 | 132 | 78 | 2800 | 3200 |
| GA 160s | 7.5 | 7.3 | 525 | 31.5 | 160 | 78 | 2900 | 3300 |
| GA 160s | 8.5 | 8.3 | 495 | 29.7 | 160 | 78 | 2900 | 3300 |
| GA 160s | 10 | 9.8 | 460 | 27.6 | 160 | 78 | 2900 | 3300 |
ImperialMetric
Units
Maximum working pressure Standard bar(e)
5.5
7.5
8.5
10
Maximum working pressure Full Feature (3) bar(e)
5.3
7.3
8.3
9.8
Capacity FAD (1) Standard / Full Feature (3) m³/min
21.2
17.8
17.0
15.6
25.4
22.2
20.8
19.0
30.1
26.4
24.8
22.9
31.5
29.7
27.6
(1) Unit performance measured according to ISO 1217, Annex C, Edition 4 (2009). Reference conditions: absolute inlet pressure 1 bar (14.5 psi) / intake air temperature 20°C (68°F).
(2) A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB). Values determined according to noise level test code ISO 2151 and noise measurement standard ISO 9614.
(3) Integrated dryer (FF): compressed air pressure dewpoint at dryer reference conditions 3°C (37°F).
(2) A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB). Values determined according to noise level test code ISO 2151 and noise measurement standard ISO 9614.
(3) Integrated dryer (FF): compressed air pressure dewpoint at dryer reference conditions 3°C (37°F).
Table test PDF (correct table settings)
Table test metric
| Type | L | W | H | |||
| mm | inch | mm | inch | mm | inch | |
| GA 90-160s | 2500 | 98.5 | 1785 | 70.3 | 2020 | 79.5 |
| GA 90-160s (FF) | 2900 | 114.2 | 1785 | 70.3 | 2020 | 79.5 |
ImperialMetric
Units
Free Air Delivery (1) is measured at:
| Standard | Full Feature | |
| 5.5 bar version at | 5 bar | 5 bar |
| 7.5 bar version at | 7 bar | 7 bar |
| 8.5 bar version at | 8 bar | 8 bar |
| 10 bar version at | 9.5 bar | 9.5 bar |
Dimensions
| Type | L | W | H | |||
| mm | inch | mm | inch | mm | inch | |
| GA 90-160s | 2500 | 98.5 | 1785 | 70.3 | 2020 | 79.5 |
| GA 90-160s (FF) | 2900 | 114.2 | 1785 | 70.3 | 2020 | 79.5 |